24 Volt ESO Plunger Arrival SensorWorks with Stainless Steel, Titanium, and Standard Steel Plungers
|

|
24 Volt ESO Electronic Shut Off Sensor (9502-2124) is a sensor that works on 24 volt
controllers. The 24 volt ESO was designed to sense a plunger as it travels past the sensor.
When the plunger makes contact with the tubing wall in close proximity to the ESO sensor
the ESO will signal arrival. The ESO does not require a stainless steel nipple. For best
results the ESO should be placed as low as possible on the wellhead to insure the plunger
travels past the sensor completely. The durable outer cover makes the ESO shock proof as
well as weather proof.
|
Mounting Instructions:
|
- Clean mounting area and make sure surface is smooth.
- Use a cable tie or a hose clamp (preferred) to secure the ESO to the wellhead.
- The two (2) magnetic contacts should be in line with the tubing or lubricator to insure the ESO can not be moved.
- Make sure the ESO can not be moved. If it moves it could cause a pre-mature shut-in.
- Silicone caulking can be used to help secure the ESO to the wellhead.
Caution:Do Not Over tighten the clamp! It will crush the sensor and it will no longer work.
|
|
(Requires Adobe Reader))
|